Custom Cable Corp. - TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
 Search Catalog
      GO   
 All Categories    TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
Specify Custom Cable Corporation . . . a name that has become synonymous with performance and reliability.
All Categories > Control Cable > TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V > View Items 

TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V

Check up to five results to perform an action.

Control Cable

larger image
For use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Request InformationCompare Items   Results per Page : 
  Results 1 - 25 of 37 1 2 

Item #

Item Name

Size (AWG/MCM)

No. of Conductors

Nominal Insualtion
Thickness (inches)

Nominal Thickness
Nylon (inches)

Nominal Jacket
Thickness (inches)

Nominal O.D.
(inches)

Nominal Weight
(LBS/MFT)

22001 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 2 (Flat) 0.015 0.004 0.045 0.180 x 0.280 41
22003 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 3 0.015 0.004 0.045 0.290 50
22004 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 4 0.015 0.004 0.045 0.310 60
22005 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 5 0.015 0.004 0.045 0.340 71
22007 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 7 0.015 0.004 0.045 0.370 89
22009 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 9 0.015 0.004 0.045 0.420 112
22010 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 10 0.015 0.004 0.045 0.440 121
22012 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 12 0.015 0.004 0.045 0.460 156
22015 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 15 0.015 0.004 0.045 0.510 169
22019 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 19 0.015 0.004 0.060 0.580 220
22020 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 20 0.015 0.004 0.060 0.590 228
22024 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 24 0.015 0.004 0.060 0.640 268
22025 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 25 0.015 0.004 0.060 0.650 279
22026 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 26 0.015 0.004 0.060 0.660 287
22030 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 30 0.015 0.004 0.060 0.710 325
22034 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 34 0.015 0.004 0.060 0.740 361
22035 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 35 0.015 0.004 0.060 0.750 371
22037 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 18 37 0.015 0.004 0.060 0.760 390
9401 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 2 (Flat) 0.015 0.004 0.045 0.195 x 0.297 49
9402 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 3 0.015 0.004 0.045 0.310 66
9403 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 4 0.015 0.004 0.045 0.340 79
9404 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 5 0.015 0.004 0.045 0.370 94
9405 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 6 0.015 0.004 0.045 0.400 109
9406 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 7 0.015 0.004 0.045 0.400 118
9408 TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V 16 9 0.015 0.004 0.045 0.460 147
  Results 1 - 25 of 37 1 2 