Custom Cable Corp. - TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
Search Catalog
By Item #
By Keyword
All Categories
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
Specify Custom Cable Corporation . . . a name that has become synonymous with performance and reliability.
All Categories
>
Control Cable
>
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
>
View Items
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
Check up to five results to perform an action.
larger image
For use in conduit, duct, tray or rack. It may be used in free air when supported by a messenger or for direct burial. Its small diameter facilitates installation and conserves space. It may be installed in cable trays in accordance with Articles 318, 340, and 725 of the NEC. It may be used in Class I, Div. II hazardous locations as allowed under Articles 318, 340 and 501. It is a Class I Cable as defined by Articles 725 and 760.
Printable Page
Email This Page
Save To Favorites
Results per Page :
25
50
100
200
Results 1 - 25 of 37
1
2
Item #
Item Name
Size (AWG/MCM)
No. of Conductors
Nominal Insualtion
Thickness (inches)
Nominal Thickness
Nylon (inches)
Nominal Jacket
Thickness (inches)
Nominal O.D.
(inches)
Nominal Weight
(LBS/MFT)
22001
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
2 (Flat)
0.015
0.004
0.045
0.180 x 0.280
41
22003
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
3
0.015
0.004
0.045
0.290
50
22004
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
4
0.015
0.004
0.045
0.310
60
22005
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
5
0.015
0.004
0.045
0.340
71
22007
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
7
0.015
0.004
0.045
0.370
89
22009
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
9
0.015
0.004
0.045
0.420
112
22010
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
10
0.015
0.004
0.045
0.440
121
22012
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
12
0.015
0.004
0.045
0.460
156
22015
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
15
0.015
0.004
0.045
0.510
169
22019
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
19
0.015
0.004
0.060
0.580
220
22020
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
20
0.015
0.004
0.060
0.590
228
22024
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
24
0.015
0.004
0.060
0.640
268
22025
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
25
0.015
0.004
0.060
0.650
279
22026
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
26
0.015
0.004
0.060
0.660
287
22030
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
30
0.015
0.004
0.060
0.710
325
22034
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
34
0.015
0.004
0.060
0.740
361
22035
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
35
0.015
0.004
0.060
0.750
371
22037
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
18
37
0.015
0.004
0.060
0.760
390
9401
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
2 (Flat)
0.015
0.004
0.045
0.195 x 0.297
49
9402
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
3
0.015
0.004
0.045
0.310
66
9403
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
4
0.015
0.004
0.045
0.340
79
9404
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
5
0.015
0.004
0.045
0.370
94
9405
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
6
0.015
0.004
0.045
0.400
109
9406
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
7
0.015
0.004
0.045
0.400
118
9408
TFFN Tray Cable - Unshielded, Type TC 90° C Dry - 75° C Wet - NEC® Article 340 - 600V
16
9
0.015
0.004
0.045
0.460
147
Results 1 - 25 of 37