Custom Cable Corp. - XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V
 Search Catalog
      GO   
 All Categories    XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V
Specify Custom Cable Corporation . . . a name that has become synonymous with performance and reliability.
All Categories > Control Cable > XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V > View Items 

XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V

Check up to five results to perform an action.

22662

larger image
UL listed and OSHA acceptable.
  • Recognized for use in Class 1, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts, conduit and aerially where supported by a messenger.
  • Specifically approved for direct burial, wet and dry locations and outdoors in cable trays where a sunlight resistant rating is required.
  • Designed for control, power, lighting, telemetering, signal and relay or traffic control where a low loss high temperature insulation is specified.




  •     Print Printable Page  
        Email Email This Page  
        Save To Favorites Save To Favorites
      
    Request InformationCompare Items   Results per Page : 
      Results 1 - 25 of 84 1 2 3 4 

    Item #

    Item Name

    Size (AWG/MCM)

    No. of Conductors

    Nominal Insualtion
    Thickness (inches)

    Nominal Jacket
    Thickness (inches)

    Nominal O.D.
    (inches)

    Nominal Weight
    (LBS/MFT)

    Shielded?

    22662 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 2 (Flat) 0.030 0.045 0.216 x 0.339 58 No
    22663 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 3 0.030 0.045 0.357 79 No
    22664 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 4 0.030 0.045 0.389 101 No
    22665 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 5 0.030 0.045 0.425 116 No
    22666 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 6 0.030 0.045 0.462 137 No
    22667 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 7 0.030 0.045 0.462 147 No
    22668 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 8 0.030 0.045 0.500 171 No
    22669 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 9 0.030 0.060 0.567 194 No
    22670 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 10 0.030 0.060 0.590 205 No
    22672 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 12 0.030 0.060 0.621 243 No
    22675 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 15 0.030 0.060 0.682 294 No
    22679 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 19 0.030 0.060 0.738 357 No
    22680 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 20 0.030 0.060 0.760 372 No
    22684 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 24 0.030 0.080 0.866 460 No
    22685 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 25 0.030 0.080 0.877 480 No
    22686 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 26 0.030 0.080 0.891 506 No
    22690 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 30 0.030 0.080 0.950 570 No
    22696 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 36 0.030 0.080 1.024 656 No
    22697 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 16 37 0.030 0.080 1.024 671 No
    22502 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 2 (Flat) 0.030 0.045 0.230 x 0.367 73 No
    22503 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 3 0.030 0.045 0.387 109 No
    22504 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 4 0.030 0.045 0.423 123 No
    22505 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 5 0.030 0.045 0.462 158 No
    22506 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 6 0.030 0.045 0.504 176 No
    22507 XHHW HYP Tray Cable-With Hypalon Jacket, TYPE TC, 90°C WET AND DRY, Shielded and Unshielded, 600V 14 7 0.030 0.045 0.504 189 No
      Results 1 - 25 of 84 1 2 3 4 

    Copyright © 2005 Custom Cable Corp. All rights reserved.

     

    Services Contact Company Profile Home Request For Quote