Custom Cable Corp. - EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location
 Search Catalog
      GO   
 All Categories    EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location
Specify Custom Cable Corporation . . . a name that has become synonymous with performance and reliability.
All Categories > Medium Voltage Power Cable > EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location > View Items 

EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location

Check up to five results to perform an action.

25030

larger image
Where NEC jurisdiction applies; as 5,000-volt nonshielded power cable, Type MV-90, for use at conductor temperatures not exceeding 90°C in wet or dry locations. Cables meet requirements of Article 310.6 of the National Electrical Code.




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Request InformationCompare Items   Results per Page : 
  Results 1 - 13 of 13 1 

Item #

Item Name

Size (AWG/MCM)

Strands

Nominal Insualtion
Thickness (inches)

Nominal Jacket
Thickness (inches)

Nominal O.D (inches)

Current-Conduit (Amps)

Current-Duct (Amps)

Nominal Weight
(LBS/MFT)

25030 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 6 7 0.125 0.080 0.650 75 85 260
25031 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 4 7 0.125 0.080 0.700 97 110 330
25032 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 2 7 0.125 0.080 0.760 130 145 435
25033 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 1 19 0.125 0.080 0.800 155 170 505
25034 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 1/0 19 0.125 0.080 0.840 180 195 590
25035 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 2/0 19 0.125 0.080 0.880 205 220 700
25036 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 3/0 19 0.125 0.095 0.960 240 250 860
25037 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 4/0 19 0.125 0.095 1.020 280 290 1020
25038 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 250 37 0.140 0.110 1.140 315 320 1210
25039 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 350 37 0.140 0.110 1.240 385 385 1525
25040 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 500 37 0.140 0.110 1.370 475 470 2130
25041 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 750 61 0.155 0.125 1.620 600 585 3090
25042 EPR Hypalon® (5000V Unshielded) Type MV90- Power Cable- Wet and Dry Location 1000 61 0.155 0.125 1.760 690 670 3960
  Results 1 - 13 of 13 1 