13120

larger image
As flame-retardant four conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  
Request InformationCompare Items   Results per Page : 
  Results 1 - 13 of 13 1 

Item #

Item Name

Size (AWG/MCM)

Strands

Nominal Insualtion
Thickness (inches)

Nominal Jacket
Thickness (inches)

Nominal O.D (inches)

Ground Wire
Size AWG

Current at 90° C- Direct Burial (Amps)

Current at 75° C- Direct Burial (Amps)

Current at 90° C Tray (Amps)

Current at 75° C Tray (Amps)

Nominal Weight
(LBS/MFT)

13120 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 8 7 0.045 0.060 0.720 12 44 40 55 50 415
13121 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 6 7 0.045 0.060 0.810 10 60 52 75 65 575
13122 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 4 7 0.045 0.080 0.960 10 76 68 95 85 840
13123 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 2 7 0.045 0.080 1.100 9 104 92 130 115 1200
13124 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 1 19 0.055 0.080 1.250 9 120 104 150 130 1545
13125 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 1/0 19 0.055 0.080 1.350 9 104 120 170 150 1835
13126 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 2/0 19 0.055 0.080 1.450 9 156 140 195 175 2195
13127 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 3/0 19 0.055 0.080 1.580 7 180 160 225 200 2800
13128 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 4/0 19 0.055 0.110 1.770 7 208 184 260 230 3460
13129 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 250 37 0.065 0.110 1.930 7 232 204 290 255 4040
13130 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 350 37 0.065 0.110 2.180 6 280 248 350 310 5475
13131 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 500 37 0.065 0.110 2.500 5 344 304 430 380 7635
13132 XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V 750 61 0.080 0.140 3.120 4 428 380 535 475 11400