Custom Cable Corp. - XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
Search Catalog
By Item #
By Keyword
All Categories
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
Specify Custom Cable Corporation . . . a name that has become synonymous with performance and reliability.
All Categories
>
Power Cable
>
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
>
View Items
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
Check up to five results to perform an action.
larger image
As flame-retardant four conductor power cables rated 600 volts, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 340 of the NEC. Type TC cables are approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.
Printable Page
Email This Page
Save To Favorites
Results per Page :
25
50
100
200
Results 1 - 13 of 13
1
Item #
Item Name
Size (AWG/MCM)
Strands
Nominal Insualtion
Thickness (inches)
Nominal Jacket
Thickness (inches)
Nominal O.D (inches)
Ground Wire
Size AWG
Current at 90° C- Direct Burial (Amps)
Current at 75° C- Direct Burial (Amps)
Current at 90° C Tray (Amps)
Current at 75° C Tray (Amps)
Nominal Weight
(LBS/MFT)
13120
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
8
7
0.045
0.060
0.720
12
44
40
55
50
415
13121
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
6
7
0.045
0.060
0.810
10
60
52
75
65
575
13122
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
4
7
0.045
0.080
0.960
10
76
68
95
85
840
13123
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
2
7
0.045
0.080
1.100
9
104
92
130
115
1200
13124
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
1
19
0.055
0.080
1.250
9
120
104
150
130
1545
13125
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
1/0
19
0.055
0.080
1.350
9
104
120
170
150
1835
13126
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
2/0
19
0.055
0.080
1.450
9
156
140
195
175
2195
13127
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
3/0
19
0.055
0.080
1.580
7
180
160
225
200
2800
13128
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
4/0
19
0.055
0.110
1.770
7
208
184
260
230
3460
13129
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
250
37
0.065
0.110
1.930
7
232
204
290
255
4040
13130
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
350
37
0.065
0.110
2.180
6
280
248
350
310
5475
13131
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
500
37
0.065
0.110
2.500
5
344
304
430
380
7635
13132
XHHW Power Cable- 4 Conductor With Ground - Type TC - NEC® ARTICLE 340 - 90°C Wet & Dry- 600V
750
61
0.080
0.140
3.120
4
428
380
535
475
11400
Results 1 - 13 of 13
1
Copyright © 2005 Custom Cable Corp. All rights reserved.